With the Power to Accurately Recommend a Diagnosis
The newly designed and patented 3CPM
Waterload Version Electrogastrogram is designed to be used to
study the true depth of Electrogastrography ability to diagnose
various neuroenteric dysfunctions as related to the digestive system,
in the uniform environment of the classic Waterload testing protocol.
Waterload Version Manual
This Electrogastrogram device is specifically designed for clinical
use, although
it may also be used for research purposes within the
confines of the standardized Waterload methodology. The
Waterload
version provides the ability to test the myoelectric gastric motility
in response to a standardized protocol of water loading that has been
extensively tested and validated against case related population
normal, to insure accuracy of the results. This device is ideally
suited to evaluate the underlying pathological gastric motility of
disorders such as gastroparesis, reflux related dyspepsia, chronic
nausea and/or vomiting, dyspepsia, as well as medication effects on
gastric motility.
Currently being used in Universities and clinics in the US and
throughout the world, this version offers an updated and easy to use
interface device. The Waterload version is designed specifically for
Universities, clinics and physician offices which are interested in
performing Electrogastrography in a closely regulated, proven and
controlled setting to insure diagnostic accuracy.
Programming-assisted internal intelligence guides the user through the
process of performing the EGG. In addition, the advanced Electrogastrogram
software
can instruct the user on identification of raw data minutes which are
artifacts, and can select the best minutes for analysis, as well as
the clinical diagnosis based upon the minutes selected.
The program itself offers
new capabilities, which include:
Closed architecture analysis of the raw
signal, providing for maximum standardization of test performance
and results
Standardized Waterload methodology, with
some flexibility in extended recording time up to 45 minutes.
Auto interpretation features for the
identification and deselecting of artifacts, the selection of good
minutes for analysis and suggestion of the clinical diagnosis based
upon minutes selected
The most advanced Fourier Transform (FFT)
analysis available for improved accuracy
Comparison of results against population
tested normal
User controlled backup and restore function
to protect against loss of data
Fully Networkable
The 3CPM Research
Electrogastrogram comes fully assembled and ready to use once rolled
out of its shipping crate. Each unit is custom assembled and
programmed for each individual customer. Internet facilitated
centralized service is included to limit downtime in the event of a
program malfunction, via a required unrestricted internet connection
provided by the end user.